| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Insufficiently protected credentials issue exists in AIPHONE IX SYSTEM and IXG SYSTEM. A network-adjacent unauthenticated attacker may obtain sensitive information such as a username and its password in the address book. |
| The Avalara for Salesforce CPQ app before 7.0 for Salesforce allows attackers to read an API key. NOTE: the current version is 11 as of mid-2024. |
| Insecure storage of the ICT MIFARE and DESFire encryption keys in the firmware
binary allows malicious actors to create credentials for any site code and card number that is using the default
ICT encryption.
|
| Exposed IOCTL with insufficient access control issue exists in cg6kwin2k.sys prior to 2.1.7.0. By sending a specific IOCTL request, a user without the administrator privilege may perform I/O to arbitrary hardware port or physical address, resulting in erasing or altering the firmware. |
| Asus RT-N12+ B1 router stores credentials in cleartext, which could allow local attackers to obtain unauthorized access and modify router settings. |
| Insufficiently protected credentials in GE HealthCare EchoPAC products |
| An issue was discovered in Kape CyberGhostVPN 8.4.3.12823 on Windows. After a successful logout, user credentials remain in memory while the process is still open, and can be obtained by dumping the process memory and parsing it. |
| VMware Avi Load Balancer contains an information disclosure vulnerability. A malicious actor with access to the system logs can view cloud connection credentials in plaintext. |
| This vulnerability allows an attacker to access parts of the application that are not protected by any type of access control. The attacker could access this path ‘…/epsilonnet/License/About.aspx’ and obtain information on both the licence and the configuration of the product by knowing which modules are installed. |
| A security vulnerability in HPE IceWall products could be exploited remotely to cause Unauthorized Data Modification. |
| H3C ER8300G2-X is vulnerable to Incorrect Access Control. The password for the router's management system can be accessed via the management system page login interface. |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Report Clients do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role. |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Track Viewer Client do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role. |
| HGW BL1500HM Ver 002.001.013 and earlier contains a use of week credentials issue. A network-adjacent unauthenticated attacker may change the system settings. |
| Utilizing default credentials, an attacker is able to log into the camera's operating system which could allow changes to be made to the operations or shutdown the camera requiring a physical reboot of the system. |
| Insufficient access checks in Visual Planning Admin Center 8 before v.1 Build 240207 allow attackers in possession of a non-administrative Visual Planning account to utilize functions normally reserved for administrators. The affected functions allow attackers to obtain different types of configured credentials and potentially elevate their privileges to administrator level. |
| The webserver utilizes basic authentication for its user login to the configuration interface. As encryption is disabled on port 80, it enables potential eavesdropping on user traffic, making it possible to intercept their credentials. |
| Logs storing credentials are insufficiently protected and can be decoded through the use of open source tools. |
| HCL DRYiCE Optibot Reset Station is impacted by a missing Strict Transport Security Header. This could allow an attacker to intercept or manipulate data during redirection. |
| Insufficiently Protected Credentials
vulnerability in OpenText Identity Manager Advanced Edition on Windows, Linux,
64 bit allows Privilege Abuse. This vulnerability could allow an
authenticated user to obtain higher privileged user’s sensitive information via
crafted payload.
This issue affects Identity Manager Advanced
Edition: from 4.8.0.0 through 4.8.7.0102, 4.9.0.0. |