| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The firmware in KAON CG3000TC and CG3000T routers contains hard-coded credentials in clear text (shared across all routers of this model) that an unauthenticated remote attacker could use to execute commands with root privileges.
This vulnerability has been fixed in firmware version: 1.00.67 for CG3000TC and 1.00.27 for CG3000T. |
| A security issue was discovered in the Kubernetes Image Builder where default credentials are enabled during the Windows image build process when using the Nutanix or VMware OVA providers. These credentials, which allow root access, are disabled at the conclusion of the build. Kubernetes clusters are only affected if their nodes use VM images created via the Image Builder project and the vulnerability was exploited during the build process, which requires an attacker to access the build VM and modify the image while the build is in progress. |
| A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| The SunPower PVS6's BluetoothLE interface is vulnerable due to its use of hardcoded encryption parameters and publicly accessible protocol details. An attacker within Bluetooth range could exploit this vulnerability to gain full access to the device's servicing interface. This access allows the attacker to perform actions such as firmware replacement, disabling power production, modifying grid settings, creating SSH tunnels, altering firewall settings, and manipulating connected devices. |
| UNI-NMS-Lite uses hard-coded credentials that could allow an
unauthenticated attacker to gain administrative privileges to all
UNI-NMS managed devices. |
| The CS5000 Fire Panel is vulnerable due to a hard-coded password that
runs on a VNC server and is visible as a string in the binary
responsible for running VNC. This password cannot be altered, allowing
anyone with knowledge of it to gain remote access to the panel. Such
access could enable an attacker to operate the panel remotely,
potentially putting the fire panel into a non-functional state and
causing serious safety issues. |
| Default credentials were present in the web portal for Airpointer 2.4.107-2, allowing an unauthenticated malicious actor to log in via the web portal |
| FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system. |
| Adtec Digital SignEdje Digital Signage Player v2.08.28 contains multiple hardcoded default credentials that allow unauthenticated remote access to web, telnet, and SSH interfaces. Attackers can exploit these credentials to gain root-level access and execute system commands across multiple Adtec Digital product versions. |
| Cypress Solutions CTM-200/CTM-ONE 1.3.6 contains hard-coded credentials vulnerability in Linux distribution that exposes root access. Attackers can exploit the static 'Chameleon' password to gain remote root access via Telnet or SSH on affected devices. |
| IBM Sterling Connect:Direct for UNIX Container 6.3.0.0 through 6.3.0.6 Interim Fix 016, and 6.4.0.0 through 6.4.0.3 Interim Fix 019 IBM® Sterling Connect:Direct for UNIX contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. |
| Precor touchscreen console P82 contains a private SSH key that corresponds to a default public key. A remote attacker could exploit this to gain root privileges. |
| A vulnerability in the .sdd file allows an attacker to read default passwords stored in plain text within the code. By exploiting these plaintext credentials, an attacker can log into affected SICK products as an “Authorized Client” if the customer has not changed the default password. |
| This vulnerability exists in ZKTeco WL20 due to hard-coded private key stored in plaintext within the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and analyzing the binary data to retrieve private key stored in the firmware of the targeted device.
Successful exploitation of this vulnerability could allow the attacker to perform unauthorized decryption of sensitive data and Man-in-the-Middle (MitM) attacks on the targeted device. |
| Precor touchscreen console P62, P80, and P82 could allow a remote attacker (within the local network) to bypass security restrictions, and access the service menu, because there is a hard-coded service code. |
| A vulnerability has been found in E-Lins H685, H685f, H700, H720, H750, H820, H820Q, H820Q0 and H900 up to 3.2 and classified as critical. This vulnerability affects unknown code of the component OEM Backend. The manipulation leads to hard-coded credentials. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.
Other related CVE's are CVE-2025-14095 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required Configuration for Exposure:
Attacker requires physical access to the analyzer.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication. |
| hippo4j 1.0.0 to 1.5.0, uses a hard-coded secret key in its JWT (JSON Web Token) creation. This allows attackers with access to the source code or compiled binary to forge valid access tokens and impersonate any user, including privileged ones such as "admin". The vulnerability poses a critical security risk in systems where authentication and authorization rely on the integrity of JWTs. |
| Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020. |
| Netis E1+ version 1.2.32533 contains a hardcoded root account vulnerability that allows unauthenticated attackers to access the device with predefined credentials. Attackers can leverage the embedded root account with a crackable password to gain full administrative access to the network device. |