| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Contec Health CMS8000 Patient Monitor is vulnerable to an out-of-bounds write, which could allow an attacker to send specially formatted UDP requests in order to write arbitrary data. This could result in remote code execution. |
| An OS command injection vulnerability within the update functionality may allow an authenticated administrator to execute unauthorized arbitrary OS commands.
Users with administrative privileges may upload update packages to upgrade the versions of Nozomi Networks Guardian and CMC.
While these updates are signed and their signatures are validated prior to installation, an improper signature validation check has been identified.
This issue could potentially enable users to execute commands remotely on the appliance, thereby impacting confidentiality, integrity, and availability. |
| A vulnerability was found in Roxy-WI up to 8.1.3. It has been declared as critical. Affected by this vulnerability is the function action_service of the file app/modules/roxywi/roxy.py. The manipulation of the argument action/service leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 8.1.4 is able to address this issue. The identifier of the patch is 32313928eb9ce906887b8a30bf7b9a3d5c0de1be. It is recommended to upgrade the affected component. |
| A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, low-privileged, local attacker to execute arbitrary commands on the underlying operating system of an affected device.
This vulnerability is due to insufficient validation of arguments for a specific CLI command. An attacker could exploit this vulnerability by including crafted input as the argument of the affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with the privileges of the currently logged-in user. |
| StepSecurity's Harden-Runner provides network egress filtering and runtime security for GitHub-hosted and self-hosted runners. Versions of step-security/harden-runner prior to v2.10.2 contain multiple command injection weaknesses via environment variables that could potentially be exploited under specific conditions. However, due to the current execution order of pre-steps in GitHub Actions and the placement of harden-runner as the first step in a job, the likelihood of exploitation is low as the Harden-Runner action reads the environment variable during the pre-step stage. There are no known exploits at this time. Version 2.10.2 contains a patch. |
| Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Rakuten Turbo 5G firmware version V1.3.18 and earlier. If this vulnerability is exploited, a remote authenticated attacker may execute an arbitrary OS command. |
| A command execution vulnerability exists in the AX2 Pro home router produced by Shenzhen Tenda Technology Co., Ltd. (Jixiang Tenda) v.DI_7003G-19.12.24A1V16.03.29.50;V16.03.29.50;V16.03.29.50. An attacker can exploit this vulnerability by constructing a malicious payload to execute commands and further obtain shell access to the router's file system with the highest privileges. |
| An remote attacker with low privileges can perform a command injection which can lead to root access. |
| A parameter within a command does not properly validate input within myPRO Manager which could be exploited by an unauthenticated remote attacker to inject arbitrary operating system commands. |
| Reachable assertions in the NGAP_FIND_PROTOCOLIE_BY_ID function of OpenAirInterface Magma v1.8.0 and OAI EPC Federation v1.2.0 allow attackers to cause a Denial of Service (DoS) via a crafted NGAP packet. |
| Syrotech SY-GOPON-8OLT-L3 v1.6.0_240629 was discovered to contain an authenticated command injection vulnerability. |
| OS command injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent attacker with credentials to execute arbitrary OS commands by sending a specially crafted request to the product. |
| A remote attacker with high privileges may use a reading file function to inject OS commands.
|
| A remote attacker with high privileges may use a writing file function to inject OS commands.
|
| A remote attacker with high privileges may use a deleting file function to inject OS commands.
|
| OS command injection vulnerability exists in AIPHONE IX SYSTEM and IXG SYSTEM. A network-adjacent authenticated attacker may execute an arbitrary OS command with root privileges by sending a specially crafted request. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root
This issue affects firmware versions before 24120701.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y). |
| An issue in Infotel Conseil GLPI v.10.X.X and after allows a remote attacker to execute arbitrary code via the insufficient validation of user-supplied input. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC models before version 241207101
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y). |
| Local privilege escalation due to OS command injection vulnerability. The following products are affected: Acronis True Image (macOS) before build 41396, Acronis True Image OEM (macOS) before build 42571. |