Search Results (133 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-10678 1 Netbirdio 1 Netbird 2026-04-15 N/A
NetBird VPN when installed using vendor's provided script failed to remove or change default password of an admin account created by ZITADEL. This issue affects instances installed using vendor's provided script. This issue may affect instances created with Docker if the default password was not changed nor the user was removed. This issue has been fixed in version 0.57.0
CVE-2025-12592 1 Vivotek 1 Camera 2026-04-15 N/A
Legacy Vivotek Device firmware uses default credetials for the root and user login accounts.
CVE-2025-1531 2026-04-15 6.5 Medium
Authentication credentials leakage vulnerability in Hitachi Ops Center Analyzer viewpoint.This issue affects Hitachi Ops Center Analyzer viewpoint: from 10.0.0-00 before 11.0.4-00.
CVE-2025-2184 1 Paloaltonetworks 1 Cortex Xdr Broker Vm 2026-04-15 N/A
A credential management flaw in Palo Alto Networks Cortex XDR® Broker VM causes different Broker VM images to share identical default credentials for internal services. Users knowing these default credentials could access internal services on other Broker VM installations. The attacker must have network access to the Broker VM to exploit this issue.
CVE-2025-29525 1 Dasan 1 H660wm 2026-04-15 5.3 Medium
DASAN GPON ONU H660WM OS version H660WMR210825 Hardware version DS-E5-583-A1 was discovered to contain insecure default credentials in the modem's control panel.
CVE-2025-29629 2026-04-15 9.1 Critical
Gardyn Home Kit firmware before master.619, Home Kit Mobile Application before 2.11.0, and Home Kit Cloud API before 2.12.2026 use weak default credentials for secure shell access. This may result in attackers gaining access to exposed Gardyn Home Kits.
CVE-2025-5124 2026-04-15 8.1 High
A vulnerability classified as critical has been found in Sony SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N and SNC-RX570N up to 1.30. This affects an unknown part of the component Administrative Interface. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. It is recommended to change the configuration settings. The vendor was contacted early about this issue. They confirmed the existence but pointed out that they "have published the 'Hardening Guide' on the Web from July 2018 to January 2025 and have thoroughly informed customers of the recommendation to change their initial passwords".
CVE-2025-55740 1 Nginx-defender Project 1 Nginx-defender 2026-04-15 6.5 Medium
nginx-defender is a high-performance, enterprise-grade Web Application Firewall (WAF) and threat detection system engineered for modern web infrastructure. This is a configuration vulnerability affecting nginx-defender deployments. Example configuration files config.yaml and docker-compose.yml contain default credentials (default_password: "change_me_please", GF_SECURITY_ADMIN_PASSWORD=admin123). If users deploy nginx-defender without changing these defaults, attackers with network access could gain administrative control, bypassing security protections. The issue is addressed in v1.5.0 and later.
CVE-2020-36915 2026-04-15 7.5 High
Adtec Digital SignEdje Digital Signage Player v2.08.28 contains multiple hardcoded default credentials that allow unauthenticated remote access to web, telnet, and SSH interfaces. Attackers can exploit these credentials to gain root-level access and execute system commands across multiple Adtec Digital product versions.
CVE-2021-47707 1 Commax 1 Cvd-axx Dvr 2026-04-15 N/A
COMMAX CVD-Axx DVR 5.1.4 contains weak default administrative credentials that allow remote password attacks and disclose RTSP stream. Attackers can exploit this by sending a POST request with the 'passkey' parameter set to '1234', allowing them to access the web control panel.
CVE-2022-50803 2026-04-15 9.8 Critical
JM-DATA ONU JF511-TV version 1.0.67 uses default credentials that allow attackers to gain unauthorized access to the device with administrative privileges.
CVE-2024-13893 2026-04-15 N/A
Smartwares cameras CIP-37210AT and C724IP, as well as others which share the same firmware in versions up to 3.3.0, might share same credentials for telnet service. Hash of the password can be retrieved through physical access to SPI connected memory. For the telnet service to be enabled, the inserted SD card needs to have a folder with a specific name created.  Two products were tested, but since the vendor has not replied to reports, patching status remains unknown, as well as groups of devices and firmware ranges in which the same password is shared. Newer firmware versions might be vulnerable as well.
CVE-2024-4622 2026-04-15 N/A
If misconfigured, alpitronic Hypercharger EV charging devices can expose a web interface protected by authentication. If the default credentials are not changed, an attacker can use public knowledge to access the device as an administrator.
CVE-2024-54015 2026-04-15 7.5 High
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials.
CVE-2024-5632 2026-04-15 N/A
Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, create a WiFi network with a default password. A user is neither advised to change it during the installation process, nor such a need is described in the manual. As the cameras from the same kit connect automatically, it is very probable for the default password to be left unchanged.
CVE-2024-6245 2026-04-15 7.4 High
Use of Default Credentials vulnerability in Maruti Suzuki SmartPlay on Linux (Infotainment Hub modules) allows attacker to try common or default usernames and passwords.The issue was detected on a 2022 Maruti Suzuki Brezza in India Market. This issue affects SmartPlay: 66T0.05.50.
CVE-2025-2119 2026-04-15 2 Low
A vulnerability was found in Thinkware Car Dashcam F800 Pro up to 20250226. It has been declared as problematic. This vulnerability affects unknown code of the component Device Registration Handler. The manipulation leads to use of default credentials. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-55051 2026-04-15 10 Critical
CWE-1392: Use of Default Credentials
CVE-2025-55110 1 Bmc 1 Control-m/agent 2026-04-15 5.5 Medium
Control-M/Agents use a kdb or PKCS#12 keystore by default, and the default keystore password is well known and documented. An attacker with read access to the keystore could access sensitive data using this password.
CVE-2025-7740 1 Hitachienergy 1 Supros 2026-04-15 N/A
Default credentials vulnerability exists in SuprOS product. If exploited, this could allow an authenticated local attacker to use an admin account created during product deployment.